TY - JOUR
T1 - Effects of cold recovery technology on the microbial drinking water quality in unchlorinated distribution systems
AU - Ahmad, Jawairia Imtiaz
AU - Liu, Gang
AU - van der Wielen, Paul W.J.J.
AU - Medema, Gertjan
AU - Peter van der Hoek, Jan
PY - 2020/4/1
Y1 - 2020/4/1
N2 - Drinking water distribution systems (DWDSs) are used to supply hygienically safe and biologically stable water for human consumption. The potential of thermal energy recovery from drinking water has been explored recently to provide cooling for buildings. Yet, the effects of increased water temperature induced by this “cold recovery” on the water quality in DWDSs are not known. The objective of this study was to investigate the impact of cold recovery from DWDSs on the microbiological quality of drinking water. For this purpose, three pilot distribution systems were operated in parallel for 38 weeks. System 1 has an operational heat exchanger, mimicking the cold recovery system by maintaining the water temperature at 25 °C; system 2 operated with a non-operational heat exchanger and system 3 run without heat exchanger. The results showed no significant effects on drinking water quality: cell numbers and ATP concentrations remained around 3.5 × 105 cells/ml and 4 ng ATP/l, comparable observed operational taxonomic units (OTUs) (~470–490) and similar Shannon indices (7.7–8.9). In the system with cold recovery, a higher relative abundance of Pseudomonas spp. and Chryseobacterium spp. was observed in the drinking water microbial community, but only when the cold recovery induced temperature difference (ΔT) was higher than 9 °C. In the 38 weeks’ old biofilm, higher ATP concentration (475 vs. 89 pg/cm2), lower diversity (observed OTUs: 88 vs. ≥200) and a different bacterial community composition (e.g. higher relative abundance of Novosphingobium spp.) were detected, which did not influence water quality. No impacts were observed for the selected opportunisitic pathogens after introducing cold recovery. It is concluded that cold recovery does not affect bacterial water quality. Further investigation for a longer period is commended to understand the dynamic responses of biofilm to the increased temperature caused by cold recovery.
AB - Drinking water distribution systems (DWDSs) are used to supply hygienically safe and biologically stable water for human consumption. The potential of thermal energy recovery from drinking water has been explored recently to provide cooling for buildings. Yet, the effects of increased water temperature induced by this “cold recovery” on the water quality in DWDSs are not known. The objective of this study was to investigate the impact of cold recovery from DWDSs on the microbiological quality of drinking water. For this purpose, three pilot distribution systems were operated in parallel for 38 weeks. System 1 has an operational heat exchanger, mimicking the cold recovery system by maintaining the water temperature at 25 °C; system 2 operated with a non-operational heat exchanger and system 3 run without heat exchanger. The results showed no significant effects on drinking water quality: cell numbers and ATP concentrations remained around 3.5 × 105 cells/ml and 4 ng ATP/l, comparable observed operational taxonomic units (OTUs) (~470–490) and similar Shannon indices (7.7–8.9). In the system with cold recovery, a higher relative abundance of Pseudomonas spp. and Chryseobacterium spp. was observed in the drinking water microbial community, but only when the cold recovery induced temperature difference (ΔT) was higher than 9 °C. In the 38 weeks’ old biofilm, higher ATP concentration (475 vs. 89 pg/cm2), lower diversity (observed OTUs: 88 vs. ≥200) and a different bacterial community composition (e.g. higher relative abundance of Novosphingobium spp.) were detected, which did not influence water quality. No impacts were observed for the selected opportunisitic pathogens after introducing cold recovery. It is concluded that cold recovery does not affect bacterial water quality. Further investigation for a longer period is commended to understand the dynamic responses of biofilm to the increased temperature caused by cold recovery.
KW - Bacterial community
KW - Biofilm
KW - Cold recovery
KW - Drinking water distribution system
KW - Drinking water quality
KW - Microbial ecology
KW - Opportunistic pathogens
U2 - 10.1016/j.envres.2020.109175
DO - 10.1016/j.envres.2020.109175
M3 - Article
AN - SCOPUS:85078206683
SN - 0013-9351
VL - 183
JO - Environmental Research
JF - Environmental Research
M1 - 109175
ER -